/ CompletedNot Applicable Prospective, Multicenter, Single-arm Clinical Investigation Evaluating the Safety, Performance and Clinical Benefit of a New Autotransfusion Device in Cardiac Surgery
Blood transfusion is at the heart of the therapeutic arsenal when there is a hemorrhage and/or blood loss during a surgery. There are two types of transfusion: the homologous one (blood from a compatible donor) and the autologous or autotransfusion method (which is done with the patient's own blood).
Although homologous transfusions can save lives, it can cause significant adverse events. Since then, multiple solutions have been developed to avoid exposing patients to these risks. It is in this context that was born the "Patient Blood Management" (PBM). Thus, the strategy in this PBM has been defined as "the appropriate use of blood and blood components, with the aim of minimizing the use of allogeneic transfusions".
In this context, particular interest has been given to autologous transfusion or autotransfusion or cell salvage, the general purpose is to reduce (or even stop) the use of allogeneic products and to reduce the risks associated with the ABO compatibility system, as well as all the adverse effects associated with allogeneic plasma and platelet transfusions.
Most autotransfusers available on the market operate by centrifugation. Autotransfusion is already a solution in Patient Blood Management and its efficiency and safety have already been optimized. However, there is still a need to improve the quality of the treated blood with an easier-to-use device that could improve the quality of the blood concentrate.
Indeed, with the current devices, it may happen that the use of allogeneic transfusions, plasma and platelets transfusions, is necessary in addition to autologous red blood cells thus reducing the interest of autotransfusion.
It is in this context that i-SEP has developed a new autotransfusion device based on a filtration method. Unlike competing devices, the i-SEP device allows the concentration of not only red blood cells (as competitive devices) but also platelets.
In this study, the i-SEP device is used in typical clinical applications of autotransfusion: cardiovascular and orthopedic surgeries, where there is a risk of hemorrhage and/or blood loss for example ≥ 500mL in cardiac surgery and ≥ 300mL in orthopedic surgery.
The study includes a screening phase (≤ 21Days), surgery phase when the i-SEP device is used (Day 0), a post-surgery phase (Day 1 - Day 6), a first follow-up visit (Day 7 ± 3) and a second follow-up visit (Day 30 ± 7).