BACKGROUNDTracheostomized patients undergoing liberation from mechanical ventilation (MV) are exposed to the ambient environment through humidified air, potentially heightening aerosol particle dispersion. This study was designed to evaluate the patterns of aerosol dispersion during spontaneous breathing trials in such patients weaning from prolonged MV.METHODSParticle Number Concentrations (PNC) at varying distances from tracheostomized patients in a specialized weaning unit were quantified using low-cost particle sensors, calibrated against a Condensation Particle Counter. Different oxygen delivery methods, including T-piece and collar mask both with the humidifier or with a small volume nebulizer (SVN), and simple collar mask, were employed. The PNC at various distances and across different oxygen devices were compared using the Kruskal-Wallis test.RESULTSOf nine patients receiving prolonged MV, five underwent major surgery, and eight were successfully weaned from ventilation. PNCs at distances ranging from 30 cm to 300 cm showed no significant disparity (H(4) = 8.993, p = 0.061). However, significant differences in PNC were noted among oxygen delivery methods, with Bonferroni-adjusted pairwise comparisons highlighting differences between T-piece or collar mask with SVN and other devices.CONCLUSIONAerosol dispersion within 300 cm of the patient was not significantly different, while the nebulization significantly enhances ambient aerosol dispersion in tracheostomized patients on prolonged MV.