/ CompletedNot ApplicableIIT An Open-label, Two-center, Randomized, Cross-over Study to Evaluate the Safety and Efficacy of Glycemic Control Using Hybrid-closed Loop vs. Advanced Hybrid Closed-loop in Young Subjects With Type 1 Diabetes
Closed-loop systems are becoming an integral part of diabetes management. These systems were uniformly proven to improve glycemic control, reduce hyperglycemia and hypoglycemia while modestly reducing HbA1c levels and improving quality of life. While overnight control is close to optimal under closed loop control, postprandial hyperglycemia during daytime remains a challenge. The advanced hybrid closed loop system was designed with an improved auto-basal control and additional auto-bolus module that delivers correction boluses automatically. In addition, this system was developed to improve user experience by significantly reducing the amount of alarms and exits from Auto Mode. Therefore, this system might have an advance in treating hyperglycemia over the hybrid closed loop that controls glucose levels by modulation of insulin basal rate only. Therefore, we propose the current study that will compare 6 weeks glycemic control using hybrid closed loop versus advanced hybrid closed loop that add correction boluses among young children and adolescents.
The objective of this study is to evaluate and compare the safety and efficacy of 6 weeks glucose control using Hybrid Closed Loop (HCL-670G) compared to Advanced Hybrid Closed Loop System (AHCL- 670G) in young subjects with sub-optimally controlled type 1 diabetes. A total of 28 subjects (age 7-14 years) will be enrolled at two investigational centers.
At the end of the cross-over study participants will be offered with an extension period, during which they will be offered to use their preferred closed-loop system for another 3 months
/ WithdrawnNot ApplicableIIT An Open-label, Two-center, Randomized, Cross-over Study to Evaluate the Safety and Efficacy of Night Closed-loop Control Using the MD-Logic Automated Insulin Delivery System Compared to Sensor Augmented Pump Therapy in Poorly Controlled Patients With Type 1 Diabetes at Home
The MD-Logic Automated Insulin Delivery System is intended for patients with type 1 diabetes mellitus for subcutaneous infusion of insulin and the continuous measurement of interstitial glucose to aid in the management of their diabetes. The product automatically adjusts basal insulin delivery and delivers correction boluses in response to real-time glucose measurements by CGM to maintain blood glucose within the desired range, to improve metabolic control without increasing the risk of hypoglycemia.
The proposed study is an open-label, two-center, randomized, cross-over study to evaluate the safety and efficacy of night closed-loop control using the MD-Logic automated insulin delivery system compared to sensor augmented pump therapy in poorly controlled patients with type 1 diabetes at home The objective of this pilot study is to evaluate the safety and efficacy of 4 weeks glucose control using the MD-Logic System in individuals with poorly controlled type 1 diabetes at patient's home