/ RecruitingNot Applicable A Prospective Randomized Single-Blind Multicenter Study to Assess the Safety and Effectiveness of the SELUTION SLR™ 014 PTCA Drug Eluting Balloon in the Treatment of Subjects With De Novo Coronary Lesions in Small Vessels
Prospective, randomized controlled, single-blind, multicenter, clinical trial to demonstrate the safety and efficacy of the SELUTION SLR 014 PTCA DEB for treatment of de novo lesions in small coronary vessels, defined as reference vessel diameter (RVD) of 2.00 mm to 2.75 mm, in support of a pre-market approval (PMA) application to the United States (US) FDA.
The Study will enroll up to 910 randomized subjects, up to 30 subjects in a parallel angiographic substudy, and up to 20 subjects in a parallel pharmacokinetic (pK) substudy, at up to 80 sites in the US, Canada, Brazil, Japan and Europe. A minimum of 50% of the subjects will be enrolled in the US.
/ Active, not recruitingNot Applicable A Prospective Randomized Multicenter Single Blinded Study to Assess the Safety and Efficacy of the SELUTION SLR™ 018 Drug Eluting Balloon in the Treatment of Subjects With Femoropopliteal Artery Lesions
This study aims to demonstrate the safety and efficacy of the SELUTION SLR™ 018 DEB compared to plain (uncoated) balloon angioplasty in the treatment of peripheral arterial disease (PAD) in the superficial femoral artery (SFA) and proximal popliteal artery (PPA).
/ RecruitingNot ApplicableIIT Feasibility and Safety of Selution SLR™ Sirolimus-eluting Balloon in Patients With Distal Internal Pudendal-penile Artery Disease and Erectile Dysfunction: : PERFECT-SELUTION First-in-man (FIM)
According to epidemiological surveys in various countries around the world, the prevalence of erectile dysfunction in men over the age of 40 is about 40%. Previous angiography studies have shown that nearly 70% of erectile dysfunction patients do have pelvic arterial stenosis. Our team leads the world in the use of percutaneous angioplasty combined with drug-eluting stents or paclitaxel-coated balloons to delineate the stenosis of the pelvic pudendal artery and penile artery The successful report of erectile dysfunction shows that the 12-month erectile function improvement rate is nearly 60%, and the vascular restenosis rate is also about 40% to 50%, obviously there is room for improvement. This study aims to observe the clinical efficacy, safety and lower restenosis rate of the newly developed "Selution SLR™ sirolimus drug sustained-release coated balloon" in patients with distal internal pudendal artery and penile artery stenosis complicated with erectile dysfunction . Compared with drug-eluting stents and paclitaxel drug-coated balloons, the Sirolimus drug-coated balloon has two advantages: one is that the clinical performance of sirolimus is much better than that of paclitaxel when used in drug-eluting stents; the other is that there is no indwelling stent in the Therefore, it can reduce the local stimulation of blood vessels and maintain the biological activity of blood vessels. Selution SLR™ sirolimus drug sustained-release coated balloon has obtained European Union approval for marketing, and has also been granted four Breakthrough Device Designation Status by the U.S. Food and Drug Administration (FDA): coronary artery disease, coronary artery disease In-stent restenosis, infra-knee artery disease, and arteriovenous canals.
100 Clinical Results associated with M.A. Med Alliance SA
0 Patents (Medical) associated with M.A. Med Alliance SA
100 Deals associated with M.A. Med Alliance SA
100 Translational Medicine associated with M.A. Med Alliance SA